The current value is not increasing Issue Description: When the washer or dryer starts its cycle, the current value does not increase as expected. Consequently, the app display does not change from blue to green. Possible Cause : There may be an issue with the current sensor, communication between the device and the app, or a delay in data update during the start of the cycle. Recommendation: Check the wiring connection between the current sensor and the Alpha-1 device, ensure sensor clip tighten to device properly, and verify that the threshold at node cloud increasing during the machine running. Clip the given split-core current transformer at the Live wire.