# The current value is not increasing

1. <span style="text-decoration: underline;"><span style="color: rgb(0, 0, 0); text-decoration: underline;">**Issue Description:**</span></span>  
    When the washer or dryer starts its cycle, the current value does not increase as expected. Consequently, the app display does not change from blue to green.

<div drawio-diagram="511"><img src="https://docs.antlysis.com/uploads/images/drawio/2025-11/Mgcvjw50cqo764zX-drawing-11-1762918041.png" alt=""/></div>

**<span style="text-decoration: underline;"><span style="color: rgb(0, 0, 0); text-decoration: underline;">Possible Cause</span></span>:**

**There may be an issue with the current sensor, communication between the device and the app, or a delay in data update during the start of the cycle.**

<span style="text-decoration: underline;"><span style="color: rgb(0, 0, 0); text-decoration: underline;">**Recommendation:**</span></span>

**Check the wiring connection between the current sensor and the Alpha-1 device, ensure sensor clip tighten to device properly, and verify that the threshold at node cloud increasing during the machine running.**

**Clip the given split-core current transformer at the Live wire.**